Open following links to identify timer and then add a comment. I have the PF1202T timer on my pool. These clocks determine when your pool pump turns on, and how long it runs. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Breakers go bad sometimes, after many years. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. A recent power outage will cause the timer to stop working. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! I currently manually turn it on and off. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Thank you for choosing Intermatic! Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. ), you should be able to discern if this is the problem, which could mean a new clock. To do this, pull the yellow-faced time dial (clockface) toward you. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. I have to reset the time every day. any suggestions about how i might avoid another situation like the above would be appreciated. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. Proceed to step 4 to check the timer itself. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? However, intermittently after the ON tripper switches pump on the pump will stop. Not sure if i need to check out the wiring, but it is a bit frustrating. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Im wanting to use T101 to wire my above ground pool pump. These are the trippers that came with the time clock. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Or is there anything else I can check? We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. My pool timer is in the off position and it is still running. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. It started lagging again a week or so ago. Hello have a question some what related. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . If all looks well, and the gears are still not turning, you may need to replace the mechanism. Any help is greatly appreciated. Posted by 4 years ago. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. Leave the paper inside your timer box so that you do not mistakenly misplace it. Any ideas? I went to the control panel and saw that the timer needle stopped just after the start pointer. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. I am using the breaker to turn on and off the pool pump. "name": "Davy Merino",
Dont know what the issue is. Also, once it reaches the tripper, the gears in the window no longer move. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. My original timer worked for 5 years then the clock stopped and I heard no sound. Please advise. Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Hello. Close. Ft. 750 Joshua Dr, Hollister, CA 95023. Any advice? Followed all directions and even watched YouTube troubleshooting videos. Did you try to flip the switch of the timeclock? Switch the breaker off at the power board. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. Jul 20, 2021. It should sit down nicely. "author": {
Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. First you want to make sure there is actually power getting from the power board to the timer itself. Step 3 Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. The most common pool timer used for inground pool pumps is the Intermatic time clock. Wont work manually or by timer function. Now remove the terminal cover on the timer. Above you said to connect white to A. and Black to 1what do I do with red? NEW CONSTRUCTION. I have a inground pool with T10003RT4 control panel. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. Now The ice and snow have melted and the cover is getting in deeper. Line is incoming, Load goes to the pump. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. The clock will also be missing 3-hours of time, so will need to be reset to the current time. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Electricity is dangerous and can kill you if you dont know what youre doing. The problem lies, where the power dies, as they say, Thanks for the response. As you release the dial, you will feel the gears engage. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. Learn more about pool care and repair. },
I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. Is there a control board, PCB in the panel that could have problems? In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Reference Manual & Buyer's Guide Another Brick in the These clocks determine when your pool pump turns on, and how long it runs. The gears in mechanical timers can get damaged. GFCI breakers trip at a very low threshold, doesnt take much. I took the electrical box cover off and check the breaker connections. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. The same happens prior to the timer reaching the off tripper. I have a sweeper set on auto on the second timer and it is working correctly. OPEN TODAY, 12PM TO 3PM. If you dont have the voltage here you have an issue with either the wiring or the breaker. make sure it hasnt tripped and is switched on. Hi Rich, is one of those wires (white?) Hi Sam, check that the dial is not warped or bent, the yellow clock dial. My intermatic timer is about two years old as well. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. If the pump comes on, you definitely have power to the timer. How do you know if your pool timer is bad? Hi, then the power for the clock must be from the switch, and not from the breaker? Jump to the troubleshooting steps below to fix the issue. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Dead as a door nail. Pools are not cheap! This is the first step to confirm if there is power or not. Also check that the motor number is compatible with your clock model. "width": "611",
Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. Any suggestions on how to troubleshoot? PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control
I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. Hello Davy, Terry here again. Replaced complete new timer assuming 5 years perfect service probably wore it out. "@type": "BlogPosting",
If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Hi Davy, I looked to see if the gears on the timer are running. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Is it possible to do this by loosening the timer screw a bit? It loses about 1.5 to 2 hours per day without any outages. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. If I have to tell you which terminals to measure, you shouldnt be doing this! Turn the metal bar until it contacts one of two plastic side tabs. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. "publisher": {
Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Hi there, },
VIDEO TOUR. Or be loose and not making good contact. Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. If I manually flip the switch nothing happens. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. The other gears move very slowly, and appear to not move at all, except for one I believe? Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? Pool pump comes on fine with the on dog, but wont turn off. Thanks in advance! Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. the ground wire? If you cant, is the manual switch stuck or jammed? HELP! It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. It randomly loses the time that it is set to. Turn the power off at the breaker box and carefully remove the wires to the clock. Make sure the middle time pointer is tight. Go for it, a little maintenance expense. Some of the replacement motors make it past quality control with the incorrect gear setup. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. Why it always stop around 10pm by itself and not moving again? It worked for a day but the day after it didnt work. Then after a bit, the pump restarts. Hi. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. It should loosen up after a few goes when the grease and gunt dissolve. Or other advice or explanation. I have the same issue currently, and it makes no sense to me so far. Wont power on pump but can hear timer clicking away. Perhaps bad wiring or a bad breaker is to blame. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Did you find the issue? Give it a little squirt of WD-40 or similar lubricant. The timer not working is for the pump. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Pop-in a new timer mechanism, and replace the wires to the previous configuration. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Or there could be a bad relay in the control panel, if you have ice cube style relays. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Can I spray the timer while there is electricity going in the timer box? I flicked the switch between on and off and it will not shut off. Im ready to send my back for a replacement. Are the gears engaged, in the center, behind the dial? Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. The circuit is protected by two ganged breakers. Okay, so lets move on to the Intermatic Pool Timer troubleshooting and figure out why your timer is not working. I guess if they look the same as before maybe the dial is warped? I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Pull the timer out and turn it to the correct time. Gold OFF tripper works for all models. Video of the Day Trippers MLS # 6354744 As it get cooler you can cut it down to 5 or 6 hr a day . DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. You can have as many ON an OFF trippes as you want. Flip it from where it is now, to the opposite side. I hope this helps. Not sure if you still answer these but I have a weird one for you. That was probably what burned the plug. },
Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. It is an ON tripper right? Thank you so much. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
"image": {
Basically 12 real life hours equals about 14 on the timer. We cover T101, T103 and T104 models of mechanical pool timers. Basically youre eliminating possibilities until you find the cause. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. The trippers push on a tab on the on/off switch. Tighten them with a wrench. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. I need to replace a timer for my pool vacuum. And does the switch look worn, where the tripper engages? Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Electrical Monke Aug 25, 2021 #22 It's broken. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. Does it need lubricant or something? "headline": "Intermatic Pool Timer Troubleshooting",
The pool timers I have had down there . Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. Yes, seen that before! Or might find something else. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. #9. You should be able to see the gears moving. However the new breaker is in a constantly tripped position. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Faulty Pump or Wiring from the Timer to the Pump. Related Reading: Should You Get a Pool Pump Timer? I noticed one thing that the power from the breaker is going into the control panel. There's an issue with the wiring between the circuit breaker and the timer. Or the switch can suffer wear over many years, and might not make solid contact. Why do we stock so many pool parts? I noticed that the on flipper was a little bit bent so I replaced it with new one. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. 4 Beds. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. Save my name, email, and website in this browser for the next time I comment. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Hey there! Take them off and inspect them and look for twists in them. One morning I noticed my pool didnt automatically turn off. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer.